Design option studies
HVAC systems, envelope, glazing and controls compared side by side, with results in energy use, operating cost and carbon.
Energy modeling and building physics
Which HVAC system, which glazing, which retrofit first? We build whole-building energy models that compare the options in energy, cost and carbon, early enough to change the design. The same models carry your LEED energy credits.
Models built for a decision, not only for a submission.
HVAC systems, envelope, glazing and controls compared side by side, with results in energy use, operating cost and carbon.
ASHRAE 90.1 Appendix G models for LEED Optimize Energy Performance, documented for the LEED review.
LEED consultingWhen the prescriptive path does not fit the design, a performance-path model shows the building complies.
Energy code simulationModels calibrated against utility data, with retrofit measures ranked by emissions, cost and LL97 exposure.
NYC Local Law 97ASHRAE Level 1 and Level 2 energy audits, with our partner PE where a seal is required.
Daylight and glare simulation for design decisions and the LEED daylight credit.
Thermal comfort and overheating studies, including CIBSE TM52 and TM59, and CFD for ventilation and air distribution.
Short loops with the design team, so the results arrive while they can still change the design.
Kick-off
What decision the model must support, and the drawings, schedules and utility data we need.
Baseline
Geometry, envelope, systems and schedules, with the assumptions written down.
Options
Each option compared on energy, cost and carbon, with the drivers explained.
Decision
A short report and a working session with the design team.
Later stages
Updated as the design develops and reused for LEED and code where the rules allow.
A selection of projects where our energy models supported design and certification.
From model to building
We model the systems at design stage and, when we are the CxA, test them before turnover against the same intent. If we also model or consult on a project where we are the CxA, we agree the arrangement with the owner at the start, so the commissioning stays independent of the design work.
At concept or schematic design for option studies, when changing the system or the facade still costs little. LEED and code models follow in design development.
Often, when the LEED version and the code path use compatible editions of ASHRAE 90.1. We tell you at the start whether one model can do both.
Drawings, the MEP narrative or equipment schedules, and for existing buildings at least a year of utility bills.
Yes. We calibrate the model against utility data before we test retrofit measures, so the savings start from what the building really uses.
Yes, anywhere in the US. Modeling is done in our office; we visit site when an existing building needs a survey.
Tell us the decision you need to make. We reply within two business days with scope, schedule and a fixed fee.
Prefer to talk? +1 (646) 296-8091 or [email protected]
LEED is a trademark of the U.S. Green Building Council. ASHRAE is a registered trademark of ASHRAE.